Lenze E94AxHE Technology Application Actuating drive - T Manual de usuario Pagina 32

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 34
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 31
9400 Technology applications | Actuator – torque
Parameter setting & configuration
Parameterisable function blocks
32 L EDS94TA10020xxxx EN 1.1 - 10/2008
4.13.3 TorqueRamp
C03539/2 Hold setpoint output
Display of input signal
bHoldOutput.
0 Setpoint output enabled
1 Hold setpoint output
C03539/3 Activate stop
Display of input signal bStop.
0 Stop not active
1 Stop requested
C03539/4...7 Activate fixed setpoint 1 ... 8
Display of input signals bJog1 ...
bJog8.
0 Jog input not active
1 Jog input active
C03539/8...11 Activate ramp parameter 1 ... 8
Display of input signals bTi1 ...
bTi8.
0 Ti input not active
1 Ti input active
C03539/12 Load external setpoint
Display of input signal
bLoadExtSpeedSetpoint.
0 Loading not active
1 Load external setpoint
C03539/13 Load motor speed
Display of input signal
bLoadActualMotorSpeed.
0 Loading not active
1 Load motor speed
Parameter Possible settings Information
Is an instance of Function
L_SdRampGenerator Ramp generator for torque setpoint
Ramp generator
(C 15)
Parameter Possible settings Information
C03550 0.001 s 1000.000 Acceleration / deceleration time
Initialisation: 0.010 s
C03551 0.001 s 10.000 S-ramp time
Initialisation: 0.001 s
C03552 -200.000 % 200.000 Setpoint at the input
Display of input signal dnIn_n.
C03553 -200.000 % 200.000 Setpoint at the output
Display of output signal dnOut_n.
Vista de pagina 31
1 2 ... 27 28 29 30 31 32 33 34

Comentarios a estos manuales