EDS94TA10020xxxx EN 1.1 - 10/2008 L 15
9400 Technology applications | Actuator – torque
Parameter setting & configuration
Torque setpoint conditioning
4.4.1 Setpoint inversion
[4-3] Setpoint inversion (schematic diagram)
Via the digital input DI3 the effective direction of the (bipolar) setpoint can be inverted, if
required.
r Parameter setting: All parameters tab category Actuator - torque Multiplexer
4.4.2 Ramp generator
[4-4] Ramp generator (schematic diagram)
In order to avoid setpoint step-changes the torque setpoint passes a ramp generator with
a parameterisable acceleration/deceleration and S-ramp time before it is transmitted to
the basic drive function "Torque follower".
r Parameter setting: Application parameters tab dialog level Overview
M
Gain Invert setpoint
LS_Torque...
M
Torque
setpoint
DI2DI3
OUT
IN
Ramp generator
Status
machine
(basic drive
functions)
Torque setpoint
AIN1
v
F
Control inputs of the function Signal configuration
Lenze setting Control input (Multiplexer parameters)
DIGIN 3 Invert setpoint C03003
M
Gain Invert setpoint
LS_Torque...
M
Torque
setpoint
DI2DI3
OUT
IN
Ramp generator
Status
machine
(basic drive
functions)
Torque setpoint
AIN1
v
F
Parameter Lenze setting
Value Unit
C03550 Acceleration / deceleration time 0.010 s
C03551 S-ramp time 0.001 s
Comentarios a estos manuales