Lenze MCH Series Drives Modbus Communications Manual de usuario Pagina 26

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 33
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 25
RG-MHMOD 22
Drive Control & Communication
AC Tech
Register
Number
(hexadecimal
representation)
Parameter
1
Parameter Name Range of Adjustment
Modbus value (decimal value)
Factory Default
77 (4D) 26 STOP 00 - Ramp
01 - Coast
00 - Coast
79 (4F) 28 SPEED SRC KEY 00 - Enabled
01 - Disabled
00 - Enabled
80 (50) 29 HAND SRC 00 - Keypad
01 - 0-10 VDC
02 - 4-20mA
03 - Preset #1
04 - Preset #2
05 - Preset #3
06 - Preset #4
07 - MOP
08 - Selected
00 - Keypad
81 (51) 30 CONTROL 00 - Normal
01 - Normal / No Hand
02 - Serial Speed
03 - Serial Speed / No Hand
04 - Serial Auto
05 - Serial Auto / No Hand
00 - Normal
82 (52) 31 UNITS 00 - Hertz
01 - RPM
02 - % Hz
03 - /SEC
04 - /MIN
05 - /HR
06 - None
07 - %
08 - PSI
09 - FPM
10 - CFM
11 - GPM
12 - IN
13 - FT
14 - /SEC
15 - /MIN
16 - /HR
17 - F
18 - C
19 - MPM
00 - Hertz
83 (53) 32 HZ MULT 10 - 65000 (.10 - 650.00) 100 (1.00)
2
84 (54) 33 UNITS DP 00 - XXXXX
01 - XXX.X
02 - XX.XX
03 - X.XXX
04 - .XXXX
00 - XXXXX
85 (55) 34 LOAD MLT 95 - 139 (95 - 139%) 100 (100%)
86 (56) 35 CONTRAST 00 - Low
01 - Medium
02 - High
02 - High
90 (5A) 39 TB5 MIN 0 - 36000 (.00 - 360.00 Hz) 0 (.00 Hz)
2
91 (5B) 40 TB5 MAX 0 - 36000 (.00 - 360.00 Hz) 0 (.00 Hz)
2
93 (5D) 42 TB10A OUT 00 - None
01 - 0 - 10 VDC
02 - 2 - 10 VDC
00 - None
94 (5E) 43 @TB10A 300 - 36000 (3.00 - 360.00 Hz) 6000 (60.00 Hz)
2
1
= Drive's programming parameter number;
2
= Two decimal places assumed (hundredths)
Vista de pagina 25
1 2 ... 21 22 23 24 25 26 27 28 29 30 31 32 33

Comentarios a estos manuales