Lenze MCH Series Drives Modbus Communications Manual de usuario Pagina 1

Busca en linea o descarga Manual de usuario para Hardware Lenze MCH Series Drives Modbus Communications. Lenze MCH Series Drives Modbus Communications User Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir

Indice de contenidos

Pagina 1 - MCH Series Drives

MCH Series Drives Modbus Communications Reference Guide

Pagina 2 - About These Instructions

RG-MHMOD 6Drive Setup & Operation4 MCH Drive Setup & Operation4.1 Serial AddressAll AC Tech drives have a Serial Address Parameter that must

Pagina 3 - Contents

7 RG-MHMODDrive Setup & Operation• Setting the control parameter to “NORMAL” or “NORM NO HAND” gives the user read/write access to the Program

Pagina 4

RG-MHMOD 8Drive Setup & Operation4.5 Unlocking & Locking Programming Parameters onlyRegisters #49 and #1 are used in Unlocking and Locking Pr

Pagina 5 - Safety Information

9 RG-MHMODDrive Setup & Operation − A Watchdog failure can be recognized by reading the drive status (AC Tech Registers #24 – 29) and looking at

Pagina 6

RG-MHMOD 10Drive Control & Communication4.9 Start/Stop, Speed Control and Parameter Change OperationThe typical sequence for a Start/Stop, Speed

Pagina 7 - Introduction

11 RG-MHMODDrive Control & Communication5 MCH Drive Control RegistersTable 6 describes the MCH Drive Control Registers in ascending order of AC

Pagina 8

RG-MHMOD 12Drive Control & CommunicationACT# (HEX representation)REGISTER NAMER/W/RSMESSAGE MIN MAX UNITS[NOTE]orSection40 (28) Keypad Speed Comma

Pagina 9 - Data & Register Format

13 RG-MHMODDrive Control & Communication5.2 Drive Control - Register #1Table 8 illustrates the Data format of Register #1, Drive Control.Table 8

Pagina 10 - Drive Setup & Operation

RG-MHMOD 14Drive Control & Communication5.3 Drive Size - Register #21Table 9 lists the MCH Series drives. Register 21 will contain the value in t

Pagina 11

15 RG-MHMODDrive Control & CommunicationNOTE 3a - Command Speed (Register #24 Bytes D1H and D1L or Register #25)• In hundredths of a Hz• Most s

Pagina 12

This documentation applies to the use of an MCH Series Variable Frequency Drive in a Modbus Network and should be used in conjunction with the MCH Ser

Pagina 13

RG-MHMOD 16Drive Control & Communication5.4.3 Control Mode - Registers #24 & 27Table 13 lists the Control Mode (Register #24 byte D4L or Regi

Pagina 14

17 RG-MHMODDrive Control & Communication5.4.6 Present Fault - Registers #24 & 29Table 16 lists the Present Fault (Register #24 byte D6H or R

Pagina 15 - 11 RG-MHMOD

RG-MHMOD 18Drive Control & Communication5.6 Kilowatt Hours - Registers #32 & 33Kilowatt hours are listed as a 32-bit value.Register #32 - Kil

Pagina 16 - 5.1 Abbreviations

19 RG-MHMODDrive Control & Communication5.11 Unlock Commands - Register #48Register #48 (Unlock Commands) unlocks commands by using 0000 for the

Pagina 17

RG-MHMOD 20Drive Control & Communication6 MCH Programming Parameters6.1 FormatNOTE - AttentionParameter list presented in Section 6.2 is valid on

Pagina 18

21 RG-MHMODDrive Control & Communication6.2 Parameter ListAC TechRegisterNumber(hexadecimalrepresentation)Parameter 1Parameter Name Range of Adj

Pagina 19

RG-MHMOD 22Drive Control & CommunicationAC TechRegisterNumber(hexadecimalrepresentation)Parameter 1Parameter Name Range of AdjustmentModbus value

Pagina 20

23 RG-MHMODDrive Control & CommunicationAC TechRegisterNumber(hexadecimalrepresentation)Parameter 1Parameter Name Range of AdjustmentModbus value

Pagina 21

RG-MHMOD 24Drive Control & CommunicationAC TechRegisterNumber(hexadecimalrepresentation)Parameter 1Parameter Name Range of AdjustmentModbus value

Pagina 22

25 RG-MHMODDrive Control & CommunicationNOTE 4 - Acceleration LimitsAcceleration LimitsHP Adjustment Range0.25 - 20 1 - 36000 (0.1 - 3600 sec)25

Pagina 23 - 5.13 Register Version

i RG-MHMODContents1 Safety Information ...

Pagina 24 - 6 MCH Programming Parameters

RG-MHMOD 26Drive Control & Communication7 Quick Start InstructionsFollow these Quick Start instructions to use ModBus Communications for basic ne

Pagina 25 - 6.2 Parameter List

27 RG-MHMODDrive Control & CommunicationUnlocking the Drive:1. The first write necessary to the drive to perform any function (start,change speed

Pagina 26 - RG-MHMOD 22

RG-MHMOD 28Drive Control & Communication7.4 Basic Drive StatusAC Tech register 24 is a 6 word entity containing the drive’s status information. T

Pagina 27 - 23 RG-MHMOD

Lenze AC Tech Corporation630 Douglas Street • Uxbridge MA 01569 • USASales: 800-217-9100 •Service: 508-278-9100www.lenze-actech.comRG-MHMOD-e7

Pagina 28 - RG-MHMOD 24

RG-MHMOD iiContents5 MCH Drive Control Registers ...115.1 A

Pagina 29

1 RG-MHMODSafety Information1 Safety Information1.1 Warnings, Cautions and Notes1.1.1 GeneralSome parts of Lenze controllers (frequency inverters,

Pagina 30 - 7 Quick Start Instructions

RG-MHMOD 2Safety Information1.1.4 Electrical ConnectionWhen working on live drive controllers, applicable national regulations for the prevention of

Pagina 31 - 7.3 Basic Drive Commands

3 RG-MHMODIntroduction2 IntroductionThis document defines the specifics required for Modbus serial communication with a Lenze-AC Tech standard MCH Ser

Pagina 32 - 7.4 Basic Drive Status

RG-MHMOD 4Introduction16 Preset Multiple Registers (4X references). Although the function is for multiple registers, we will accept only a single reg

Pagina 33 - Lenze AC Tech Corporation

5 RG-MHMODData & Register Format3 Data Representation - Internal and External3.1 Register FormatAll registers are 16 bits. The data within the

Comentarios a estos manuales

Sin comentarios