Parameter setting
6-2
BA2112EN
Assignment of process input data words
Meaning for
Byte No.
Unit cont rol
C0009 = 11
DRIVECOM control
C0009
≠ 11, 12
User defined
control profile
C0009 = 12
(only 8200 vector / 93XX)
1 HIGH byte; bit 8-15
2 LOW byte; bit 0-7
s
a
us w
s
a
us w
n
:
-
1 HIGH byte; bit 8-15
82XX / 8200 vector: Actual speed
2 LOW byte; bit 0-7
u
93XX: Freely configurable
n
:
-
6.1.1.2 Process-data assignments for 82XX
Structure of the PO-data response (data to drive)
Byte 1 Byte 2 Byte 3 Byte 4
Control word
High byte
Control word
Low byte
Setpoint
High byte
Setpoint
Low byte
Control word: see chapter 6.1.3.2
Setpoint: frequency setpoint
Here the frequency setpoint is preselected as process data word. The normalization is here
indicated as signed value with
24000 = 480 Hz.
Structure of the PI data response (data from drive)
Byte 1 Byte 2 Byte 3 Byte 4
Status word
High byte
Status word
Low byte
Actual value
High byte
Actual value
Low byte
Status word: see chapter 6.1.3.3.
Actual value: act. frequency value
The actual frequency value is provided as signed normalization
24000 = 480 Hz.