Lenze EMB9352−C Manual de usuario Pagina 80

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 174
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 79
Dimensioning
Dimension brake chopper and brake resistor
5
80
EDBMB935X DE/EN/FR 13.0
Step 3: Calculate the number of brake choppers per brake resistor
N
Brm
+
P
gen,ave
(3s)
N
R
@ P
N
(U
ch
)
N
Brm
Number of brake choppers per brake resistor
N
R
Number of brake resistors
P
gen,ave
(3 s) Highest average regenerative power over 3 s (Fig. 3)
P
rated
(U
ch
) Rated brake chopper power, based on switching threshold U
ch
( 75)
Always round the result up to the next integer!
If you want to use only one brake chopper per brake resistor:
ƒ Gradually increase the number of brake resistors in the formula until
N
Brm
£ 1 (one brake chopper per brake resistor).
Note!
Technically, both solutions are possible. Please check the solutions
for cost effectiveness.