Pagina 1 - Series Drives

Tmd Series Drives Modbus Communications Reference Guide

Pagina 2 - About These Instructions

RG-TDMOD 6Drive Setup & Operation2.4 Universal RegistersLenze-AC Tech manufactures several drive families. Currently the QC, MC, MCH, SC, TC, smd

Pagina 3 - Contents

7 RG-TDMODDrive Setup & Operation3 Data Representation - Internal and External3.1 Register FormatAll registers are 16 bits. The data within th

Pagina 4

RG-TDMOD 8Drive Setup & Operation4 Tmd Drive Setup & Operation4.1 Control ParameterIn order to communicate using Modbus protocol, the Tmd Con

Pagina 5 - Safety Information

9 RG-TDMODDrive Setup & Operation4.4 Watchdog TimerThe Tmd drive is equipped with a Serial Link “Watchdog Timer”. If the Modbus Master wishes t

Pagina 6

RG-TDMOD 10Drive Control & Communication4.5 Unlocking & Locking ControlsRegisters #48 and #1 are used in Unlocking and Locking Controls.• A

Pagina 7 - Introduction

11 RG-TDMODDrive Control & Communication4.8 Normal Control Operation Sequence1. Power up drive.2. Set parameter C01 (Control Source Setpoint)

Pagina 8

RG-TDMOD 12Drive Control & Communication5 Tmd Drive Control RegistersTable 6 describes the Tmd Drive Control Registers in ascending order of Tmd R

Pagina 9 - Data & Register Format

13 RG-TDMODDrive Control & Communication5.1 AbbreviationsTable 7 lists the abbreviations used in Table 6 Tmd Drive Control Registers:Table 7: Abb

Pagina 10 - Drive Setup & Operation

RG-TDMOD 14Drive Control & CommunicationNOTE 1 - Drive Control• During each write to Register #1 only one bit should be set in the drive control

Pagina 11

15 RG-TDMODDrive Control & Communication5.4 Drive Hardware Configuration - Register #22Table 10 lists the Tmd Drive Hardware Configuration, Regist

Pagina 12

This documentation applies to the use of an Tmd Series Variable Frequency Drive in a Modbus Network and should be used in conjunction with the Tmd Ser

Pagina 13

RG-TDMOD 16Drive Control & CommunicationNOTE 4b - Actual Speed (Register #24 Bytes D2H and D2L or Register #25)• In tenths of a Hz• Most signific

Pagina 14 - Monitoring Only Operation

17 RG-TDMODDrive Control & Communication5.5.4 Control Mode - Registers #24 & 27Table 14 lists the Control Mode (Register #24 byte D4L or Reg

Pagina 15

RG-TDMOD 18Drive Control & Communication5.5.7 Present Fault - Registers #24 & 29Table 16 lists the Present Fault (Register #24 byte D6H of Re

Pagina 16 - Drive Control Registers

19 RG-TDMODDrive Control & Communication5.7 Serial Speed - Register #40This register enables the user to set the serial speed to desired value.•

Pagina 17 - 5.1 Abbreviations

RG-TDMOD 20Drive Control & Communication6 Tmd Programming Parameters6.1 FormatNOTE - AttentionParameter list presented in Section 6.2 is valid onl

Pagina 18

21 RG-TDMODDrive Control & Communication6.2 Parameter ListParameter No. 1Tmd Register #(hexadecimalrepresentation)Parameter Name Range of Adjust

Pagina 19

RG-TDMOD 22Drive Control & CommunicationParameter No. 1Tmd Register #(hexadecimalrepresentation)Parameter Name Range of AdjustmentModbus value (de

Pagina 20

23 RG-TDMODDrive Control & CommunicationParameter No. 1Tmd Register #(hexadecimalrepresentation)Parameter Name Range of AdjustmentModbus value (d

Pagina 21

RG-TDMOD 24Drive Control & CommunicationParameter No. 1Tmd Register #(hexadecimalrepresentation)Parameter Name Range of AdjustmentModbus value (de

Pagina 22

25 RG-TDMODDrive Control & CommunicationParameter No. 1Tmd Register #(hexadecimalrepresentation)Parameter Name Range of AdjustmentModbus value (d

Pagina 23 - 5.10 Register Version

i RG-TDMODContents1 Safety Information ...

Pagina 24 - Programming Parameters

RG-TDMOD 26Drive Control & CommunicationNOTE 5 - Tmd Fault HistoryParameters c61 (Present Fault), c62 (Last Fault), c63 (Last but one Fault) and c

Pagina 25 - 6.2 Parameter List

27 RG-TDMODDrive Control & Communication7 Quick Start InstructionsFollow these Quick Start instructions to use ModBus Communications for basic n

Pagina 26 - RG-TDMOD 22

RG-TDMOD 28Drive Control & Communication7.2 Drive Control1. Please be advised that while the drive is under network control the local STOP circu

Pagina 27 - 23 RG-TDMOD

29 RG-TDMODDrive Control & Communication7.4 Basic Drive StatusAC Tech register 24 is a 6 word entity containing the drive’s status information.

Pagina 28 - RG-TDMOD 24

AC Technology Corporation630 Douglas Street • Uxbridge MA 01569 • USASales: 800-217-9100 •Service: 508-278-9100www.lenze-actech.comRG-TDMOD-e3

Pagina 29 - 25 RG-TDMOD

RG-TDMOD iiContents5 Tmd Drive Control Registers ...125.1 A

Pagina 30

1 RG-TDMODSafety Information1 Safety Information1.1 Warnings, Cautions and Notes1.1.1 GeneralSome parts of Lenze controllers (frequency inverters,

Pagina 31 - 7 Quick Start Instructions

RG-TDMOD 2Safety Information1.1.4 Electrical ConnectionWhen working on live drive controllers, applicable national regulations for the prevention of

Pagina 32 - 7.3 Basic Drive Commands

3 RG-TDMODIntroduction2 IntroductionThis document defines the specifics required for Modbus serial communication with a Lenze-AC Tech standard Tmd Ser

Pagina 33 - 7.4 Basic Drive Status

RG-TDMOD 4Introduction2.2.3 Network TerminationFor an RS-485 network it is essential to install the specified termination resistors (120W), i.e. one a

Pagina 34 - AC Technology Corporation

5 RG-TDMODData & Register FormatD. The function codes supported by the Tmd drives are:03 Read Holding Register (4X references). In general we

Comentarios a estos manuales