14 Parameter reference
14.3 Parameters of the communication module for slot MXI2
110
Lenze · E94AYCPM communication module (PROFIBUS®) · Communication Manual · DMS 12.0 EN · 11/2012 · TD17
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C14920
C14990
Parameter | Name:
C14920 | Display: DIP switch setting
Data type: UNSIGNED_8
Index: 9655
d
= 25B7
h
Display of the current DIP switch setting
• The displayed value corresponds to the sum of the individual DIP switch values 1 ... 64.
• The active station address is displayed under C14864
.
• Possible DIP switch settings
( 31)
Display area (min. value | unit | max. value)
0 255
; Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C14990 | ICM statistic counter
Data type: UNSIGNED_16
Index: 9585
d
= 2571
h
Available from software version 01.21!
This code is for device-internal use only and must not be overwritten by the user!