7 Commissioning
DIP switch settings
EDK94AYCIB DE/EN/FR/ES/IT 1.0
48
H1inbet−ueb−rate einstellen
Setting the number of process data words (PD)
ƒ You can use switches 1 to 4 or the code C13893 / C14893 to set the number of
process data words.
ƒ 0 to 10 process data words can be used.
ƒ The current setting is shown in C13860/2 / C14860/2.
Note!
The total number of data words (PD + PCP) must be between 1 and 10.
Impermissible settings are signalled by the "BE" LED (flashes
51) red.
The communication module then works internally with the following values:
ƒ PD = 2 (words)
ƒ PCP = 1 (word)
DIP switch Number of PD
Switch
Max. number
of PCP
1 2 3 4
12345678
ON
OFF
0 OFF OFF OFF OFF
4
1 OFF OFF OFF ON
2 OFF OFF ON OFF
3 OFF OFF ON ON
4 OFF ON OFF OFF
5 OFF ON OFF ON
6 OFF ON ON OFF
7 OFF ON ON ON
2
8 ON OFF OFF OFF
9 ON OFF OFF ON 1
10 ON OFF ON OFF 0