Function library LenzeDrive.lib
Special functions
2.7.5 Process controller (L_PCTRL)
2−79
L
LenzeDrive.lib EN 1.7
2.7.5 Process controller (L_PCTRL)
This FB is used, for instance, as a higher−level controller (dancer position controller, tension
controller, pressure controller, etc.).
Setpoint and actual value are sent to the process controller via the corresponding inputs and
processed according to the selected control algorithm (PID−, PI− or P−algorithm).
L _ P C T R L
± 1 6 3 8 4
R E S E T
n A d a p t _ a
V p 2
V p
n S e t _ a
n A c t _ a
b I n A c t _ b
b I O f f _ b
n I n f l u _ a
d n T i r
d n T i f
2
3
s o l l 1 s o l l 2
V p
V p 2
V p 3
n S e t 1 A d a p t
n V p 2 A d a p t
3
2
1
0
b y P C h a r a c t e r i s t i c
n V p
b B i U n i p o l a r
d n T n
n K d
n O u t _ a
n V p
n V p
n V p 2 A d a p t
n V p 3 A d a p t
n S e t 2 A d a p t
n A c t V p
Fig. 2−75 Process controller (L_PCTRL)
VariableName DataType SignalType VariableType Note
nAdapt_a Integer analog VAR_INPUT Gain V
p
Value range: ±32767
You can alter the gain online.
nSet_a Integer analog VAR_INPUT Input of the process setpoint.
Range of possible values: ±32767
The rate of change of step−change signals can be
slowed by using the ramp generator (with dnTir
and dnTif).
nAct_a Integer analog VAR_INPUT Actual value input
Value range: ±32767
bInAct_b Bool binary VAR_INPUT Deactivation of the process controller.
You can carry out this function online.
bIOff_b Bool binary VAR_INPUT Set I−component to 0.
You can carry out this function online.
nInflu_a Integer analogs VAR_INPUT Evaluation or suppression of the output signal.
Value range: ±32767
nOut_a Integer analog VAR_OUTPUT Output signal. Value range ±16384 (bipolar), or
0 ... 16384 (unipolar)
nActVp Integer − VAR_OUTPUT Shows the actual gain.
nVp Integer − VAR CONSTANT RETAIN Gain V
p
(10 1.0)
dnTn Double integer − VAR CONSTANT RETAIN Integral−action time T
n
(20 20 ms)
nKd Integer − VAR CONSTANT RETAIN Differential component Kd (10 1.0)
nVp2Adapt Integer − VAR CONSTANT RETAIN Vp2 − process controller adaptation (64 1.0)
nVp3Adapt Integer − VAR CONSTANT RETAIN Vp3 − process controller adaptation (64 1.0)
nSet1Adapt Integer − VAR CONSTANT RETAIN Set1 − process controller adaptation (16384 100.00
%)
nSet2Adapt Integer − VAR CONSTANT RETAIN Set2 − process controller adaptation (16384 100.00
%)
byPCharacteristic Byte − VAR CONSTANT RETAIN Function selection for the provision of the P−gain
dnTir Double integer − VAR CONSTANT RETAIN Acceleration time T
ir
(1000 1.000 s)
dnTif Double integer − VAR CONSTANT RETAIN Deceleration time T
if
(1000 1.000 s)
bBiUnipolar Bool − VAR CONSTANT RETAIN Value range of the output signal