2.7.4 Speed preconditioning (L_NSET)
Function library LenzeDrive.lib
Special functions
2−74
L
LenzeDrive.lib EN 1.7
Variable name CommentVariable typeSignal typeData type
nNAdd_a Integer analog VAR_INPUT Provided for additional setpoint; other signals are
permissible.
bExternalCINH Bool binary VAR_INPUT Resets the ramp function generator and the additional
ramp generator.
nNOut_a Integer analog VAR_OUTPUT Speed setpoint (16384 100 % n
max
(C0011))
bRfgIEqO_b Bool binary VAR_OUTPUT Status check
dnTir Double integer VAR CONSTANT RETAIN Acceleration time Tir for the main setpoint
dnTif Double integer VAR CONSTANT RETAIN Deceleration time Tif for the main setpoint
adnTir[0...14] Array of double
integers
VAR CONSTANT RETAIN Acceleration time Tir for the main setpoint
adnTif[0...14] Array of double
integers
VAR CONSTANT RETAIN Deceleration time Tif for the main setpoint
anJogSetValue[0...14] Array of integers VAR CONSTANT RETAIN Selectable fixed speeds
bSShapeActive Bool VAR CONSTANT RETAIN S−curve ramp generator characteristic for the main
setpoint
nTiSShaped Integer VAR CONSTANT RETAIN T
i
−time for the S−curve ramp generator
byArithFunction Byte VAR CONSTANT RETAIN Arithmetic function, combines mains and additional
setpoints.
dnTirAdd Double integer VAR CONSTANT RETAIN Acceleration time T
ir
for the additional setpoint
dnTifAdd Double integer VAR CONSTANT RETAIN Deceleration time T
if
for the additional setpoint
nlEqOHysteresis Integer VAR CONSTANT RETAIN Ramp generator threshold for the main setpoint
Parameter codes of the instances
Variable name L_NSET1 Setting range Lenze
dnTir C0012 0.000 ... 999.900 sec 0.000
adnTir[0...14] C0101/1 ... 15 0.000 ... 999.900 sec 0.000
dnTif C0013 0.000 ... 999.900 sec 0.000
adnTif[0...14] C0103/1 ... 15 0.000 ... 999.900 sec 0.000
anJogSetValue[0...14] C0039/1 ... 15 −199.99 ... 199.99% 0.00
bSShapeActive C0134 0 ... 1 0
nTiSShaped C0182 0.01 ... 50.00 sec 20.00
byArithFunction C0190 0 ... 5 0
dnTirAdd C0220 0.000 ... 999.900 sec 0.000
dnTifAdd C0221 0.000 ... 999.900 sec 0.000
nlEqOHysteresis C0241 0.00 ... 100.00% 1.00
2.7.4.1 Main setpoint channel
The signals in the main setpoint channel are limited to the range of ±32767.
The signal at nNSet_a is initially led by the function JOG−select.
A selected JOG value switches the input nNSet_a inactive. Then the following signal
conditioning uses the JOG value.