Lenze DDS Function library Drive Manual de usuario Pagina 38

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 103
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 37
2.2.16 S−ramp generator (L_SRFG)
Function library LenzeDrive.lib
Analog signal processing
2−28
L
LenzeDrive.lib EN 1.7
Function
Load ramp generator
By using bLoad_b = TRUE loads the ramp generator with the signal at nSet_a.
This value is instantly accepted and output to nOut_a. No ramp−up or ramp−down through an
S−curve takes place.
As long as bLoad_b remains = TRUE, the ramp generator is disabled.
Acceleration and jerk
The maximum acceleration and the jerk can be adjusted separately.
n I n _ a
n O u t _ a
t
t
t
t
d w T i
d w T i
d w J e r k
R
Q
n
D e l t a O u t _ a
Fig. 2−31 Line diagram
Acceleration
Jerk
Max. acceleration:
By using dwTi you set the positive as well as the negative acceleration.
The setting is calculated according to the formula:
1s @ 100%
dwTi
Jerk:
By using dwJerk you set up a jerk−free acceleration of the drive.
The jerk is entered in [s] until the ramp generator operates with maximum acceleration (see
Fig. 2−31).