
Wiring the device modules
Function modules
8
74
EDK94AMH24 DE/EN/FR/ES/IT 3.1
8.2 Function modules
Use these modules in slot þ MXI1 or þMXI2 oMMI oMSI.
Digital frequency
E94AYFLF004
Connections
Pos. Description
X9 Input for digital frequency, 9−pole Sub−D plug
X10 Output for digital frequency, 9−pole Sub−D socket
X9 Pin Designation Explanation
1
6
5
9
1 B
TTL input signal by encoder or encoder simulation
2 A
3 A
4 +5 V Regulated voltage supply for encoder
(pin 8 = sense must be used, max. control range 5 ... 9 V)
5 GND −
6 Z
TTL input signal by encoder or encoder simulation
7 Z
8
The function of this cable has to be set in the basic device:
l S
l Lc
l E
l Sense (sensor lead for voltage regulation, Lenze setting)
l Lamp control
l Enable
SUBD09010
9 B TTL input signal by encoder or encoder simulation
Comentarios a estos manuales