L-force Loader
Control via script files
Structure of the script file
30 DMS 4.0 EN - 07/2007 L
O Tip!
The script is not tested for correctness before it is being processed, i.e. script
processing does not stop before an error occurs. The error can be analysed and
eliminated using the log file.
Communication settings - [COMMUNICATION] section
General settings - [COMMON] section
Key Parameter
Baudrate Baud rate of the system bus in kBaud.
The baud rate selection in the script is optional.
If the baud rate is not defined in the script, the value set in the system bus
configurator will be used.
Key Parameter
NumberOfDevices Number of the target systems to be programmed (max. 63).
ShowProcessing Status window display:
0 = Status window not displayed (standard setting).
1 = Status window displayed.
MaxNumberOfErrors The latest version no longer supports this entry and ignores it, if necessary (e.g. in older
script files).
ExitAfterDownload Automatic stop of »L-force Loader« after the script has been processed:
0 = »L-force Loader« does not stop after processing is completed (standard setting).
1 = »L-force Loader« stops after processing is completed.