L-force Loader
Operation
How to download data
5.5.1 Parameter set transfer
The function area provides the following functions for the download of GDC parameter set
files:
Assignment of device descriptions
The GDC parameter set file includes the codes to be transferred with the corresponding
initialisation values. The parameter set transfer, however, requires additional information
about the code type. This information is generated from the corresponding device
description.
The »L-force Loader« tries to assign these device descriptions automatically by searching
the directory which has been the source for the parameter set file for the corresponding
device description.
r If a directory does not include the corresponding device description, the search will be
continued in the directories configured via the DriveServer menu commands
ConfigurationPDB paths....
Command Function
Duplication of parameter set At the parameter set transfer, some codes of the parameter set are not transferred
to the target system. These are, among others:
C0009 - AIF device address
C0125 - AIF baud rate
C0058 - Rotor position
All codes not transferred to the target system are listed in a note dialog before the
parameter set transfer starts.
Replacement device Codes C0009, C0125 and C0058 are also transferred to the target system.
Note: LECOM does not support the "Replacement device" function!