5 Commissioning
Possible settings via the front DIP switches
EDKMF2113 DE/EN/FR 5.1
62
H1inbet−Merker_hidden statusanzeige
Setting the number of process data words (PCD)
Note!
ƒ Impermissible settings are indicated by the yellow LED (communication)
(69).
ƒ The current switch position of S1...S4 for the number of process data
words (PCD) can be displayed under code C1915.
ON
OFF
OPEN
12345678
Length
PD
2113IBU005
PCD
Switches
Max. number of parameter data
words (PCP)
S1 S2 S3 S4
1 OFF OFF OFF ON
4
2 OFF OFF ON OFF
3 OFF OFF ON ON
4 OFF ON OFF OFF
5 OFF ON OFF ON
6 OFF ON ON OFF
7 OFF ON ON ON
2
8 ON OFF OFF OFF
9 ON OFF OFF ON 1
10 ON OFF ON OFF 0