Vista de pagina 26
Electrical installation
Installation of a DC-typical drive system
5
27
EDBCSXKXXX EN 1.0
Filtering
ƒ Use RFI filters and mains chokes which are assigned to the power supply modules:
RFI filters reduce impermissible high-frequency interferences to a permissible
value.
Mains chokes reduce low-frequency interferences which depend on the motor
cable and its length.
Shielding
ƒ Connect the motor cable shield to the axis module
with the EMC accessories ECSZS000X0B.
to the mounting plate below the axis module with a large surface.
Recommendation: For the shield connection, use earthing clamps on bare metal
mounting s urfaces.
ƒ If contactors, motor-protecting switches or terminals are located in the motor cable:
Connect the shields of the connected cables to the mounting plate, too, with a
surface as large as possible.
ƒ Connect the shield in the motor terminal box or on the motor housing to PE:
Metal glands at the motor terminal box ensure a connection of the shield and the
motor housing.
ƒ Shield the control cables:
Connect both shields of the digital control cables.
Connect one shields of the analog control cables.
Always connect the shields to the shield connection at the controller over the
shortest possible distance.
ƒ Using the axis modules in residential areas:
Additionally dampen the shield in order to limit the interfering radiation: 10 dB .
This can be realised by using standard, closed, metallic, and earthed control
cabinets or boxes.
Earthing
ƒ Earth all metallically conductive components (power supply module, capacitor
module, axis module, RFI filter, motor filter, mains choke) using suitable cables
connected to a central point (PE bar).
ƒ Maintain the minimum cross-sections prescribed in the safety regulations:
For the EMC, not the cable cross-section is important, but the surface and the
contact with a cross-section as large as possible, i.e. large surface.