Technical data
General data and operating conditions
4
35
LDCDS−2700 DE/EN 3.0
4 Technical data
4.1 General data and operating conditions
Conformity and approval
Conformity
CE
EN 61000−6−4
EN 61000−6−2
EMC Directive Class A, industrial premises
Approval
UL UL 508
CSA C22.2
Programmable Controller Accessories, battery units
(File−No. E23641)
Other
RoHS Products lead−free in accordance with CE Directive
2011/65/EU
Protection of persons and equipment
Safety VDE0805
(EN60950),
VDE0870, UL
Enclosure IP 20
Class of protection 3
Ambient conditions
Climatic
Storage −20 ... +40 °C
Transport −20 ... +40 °C
Operation
Load l 0 ... +55 °C
l 0 ... +50 °C in UL−compliant facilities
Discharging l −20 ... +55 °C
l −20 ... +50 °C in UL−compliant facilities
Relative humidity 0 ... 90 %, no condensation
Site altitude < 4000 m amsl
Mounting conditions
Place of installation Close to the industrial PC (cable length 2.5 m) with
fixed installation; extension cables are available
Mounting position Vertical with connecting cable at the bottom