Lenze ACCU−PACK Manual de usuario Pagina 30

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 41
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 29
Safety instructions
Safety instructions for the installation according to U
L
2
30
LDCDS−2700 DE/EN 3.0
2.3 Safety instructions for the installation according to U
L
Original − English
Approval
Underwriter Laboratories (UL), UL508 and CSA C22.2 No. 142−M1987, (UL File
Number E236341)
Ratings
ƒ Input
18 ... 30 V DC, max. 0.6 A
ƒ Output
max. 30 V DC, max. 6.5 A
ƒ Max. ambient temperature 50 °C
ƒ The battery unit are open type accessory for programmable controller
systems. The battery unit serves as uninterruptible power system in case
of loss of voltage.
Warnings!
Field Wiring Markings
Wiring Terminal MC 1,5/2−STF−3,81:
ƒ Use copper wire 75 °C only.
ƒ AWG 16 ... AWG 14 (1.3 mm
2
... 2.1 mm
2
)
ƒ Torque 1.95 lb−in ... 2.2 lb−in (0.22 Nm ... 0.25 Nm)
Battery
ƒ Dispose of used battery according to the regulation of recycling
or waste.
Vista de pagina 29
1 2 ... 25 26 27 28 29 30 31 32 33 34 35 ... 40 41

Comentarios a estos manuales

Sin comentarios