Technical data
3-1
L _^ONMObk
3 Technical data
3.1 Features of the 2102 fieldbus module
The 2102 fieldbus module has the following features:
Different communication media:
RS232 (LECOM-A)
RS485 (LECOM-B)
Optical fibre (LECOM-LI)
LECOM protocol V2.0
The baud rate can be set to 1200, 2400, 4800, 9600 or 19200 baud (bit/s).
Parameter setting via controller code numbers
3 Diagnostic LEDs
Electrical isolation between control stage and power stage
Electrical isolation of the I/O terminals of 821X, 8200 vector, 822X and 93XX
Easy installation
3.2 General data and application conditions
Field Values
Communication media RS232 (LECOM-A): copper conductor
RS485 (LECOM-B): copper conductor
(LECOM-LI): optical fibre
Protocol LECOM-A/B V2.0
Character
Format
7 bit ASCII
1Stopbit
1Startbit
1 Parity bit (even)
Baud rate [bits/s] 1200, 2400, 4800, 9600, 19200
Ambient temperature During operation: 0 to +50 °C
Transport: –25 to +70
°C
Storage: –25 to +55
°C
Permissible moisture Class 3K3 to EN 50178 (without condensa t io n, average relat ive humidity 85%)
24-V-DC-
Voltage supply
820X / 8200 vector (obser ve chapter 4.3): only external supply
821X / 822X / 8200 vector (o bser ve chapter 4.3) / 93XX: internal o r external supply