Electrical installation
Power terminals
4
84
EDKCSCE040 DE/EN/FR 3.0
Assignment of the plug connectors
Terminal Function Electrical data
X21 Mains connection
X21/L1 Mains phase L1
Dependent on application and
type
0 ... 480 V
up to 31.3 A (
70)
X21/L2
Mains phase L2
X21/L3 Mains phase L3
X21/PE Connection of PE conductor
X22 DC−bus voltage connection
X22/BR0
Internal brake resistor, connection 1
Dependent on application and
type
0 ... 770 V
up to 38.5 A (
70)
X22/BR1
External brake resistor, connection 1
X22/+UG
Internal/external brake resistor, connection 2
X22/+UG
DC−bus voltage supply, plus
X22/−UG
DC−bus voltage supply, minus
X22/PE
Connection of PE conductor
Cable cross−sections and screw−tightening torques
Cable type Wire end ferrule Possible cable
cross−sections
Tightening torque Stripping length
Terminal strips X21 and X22
Rigid ˘
0.2 ... 10 mm
2
(AWG 24 ... 8)
1.2 ... 1.5 Nm
(10.6 ... 13.3 lb−in)
5 mm for screw
connection
10 mm for spring
connection
Flexible
Without wire end
ferrule
0.2 ... 10 mm
2
(AWG 24 ... 8)
With insulated wire
end ferrule
0.25 ... 6 mm
2
(AWG 22 ... 10)
With insulated
TWIN wire end
ferrule
0.25 ... 4 mm
2
(AWG 22 ... 12)
Shielded cables
The following factors decisively determine the effect of the shielded cables:
ƒ Good shield connection
Ensure a contact surface as large as possible
ƒ Low shield resistance
Only use shields with tin−plated or nickel−plated copper braids (shields
with steel braids cannot be used).
ƒ High overlap rate of the braid
At least 70 ... 80 % with 90° overlap angle
The ECSZS000X0B shield mounting kit includes a wire clamp and shield sheet.