Technical data
Operating conditions
4
EDK82ZAFPC-010 DE/EN/FR 6.0
49
H1_Daten-Schutzisolierung_010
Operating conditions
Ambient conditions
Climate
Storage IEC/EN 60721-3-1 1K3 (-25 to +60 °C)
Transport IEC/EN 60721-3-2 2K3 (-25 to +70 °C)
Operation Corresponding to the data of the Lenze standard device used (see
documentation of the standard device).
Pollution EN 61800-5-1 Degree of pollution 2
Degree of protection IP20 (protection against accidental contact according to NEMA 250 type 1)
Protective insulation
Protective insulation between bus and ... Type of insulation (acc. to EN 61800-5-1)
8200 vector power stage
Reinforced insulation
Reference earth / PE (X3.2/7, X3.3/7)
Functional insulation
External supply (X3.2/59)
Functional insulation
Supply for CINH (X3.3/20)
Functional insulation
Controller inhibit, CINH (X3.3/28)
Functional insulation