Lenze E94AxHE Technology Application Positioning sequenc Manual de usuario Pagina 25

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 78
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 24
EDS94TA10060xxxx EN 1.2 - 03/2010 L 25
9400 Technology applications | Positioning sequence control
Short setup
Step 4: Parameterising the multiplexer for the digital outputs
4.7 Step 4: Parameterising the multiplexer for the digital outputs
1. Go to the All parameters tab.
2. Set the following multiplexer parameters:
Parameter Setting
C03100/2 X digital output 2 of Homing completed
C03100/3 X digital output 3 of Sequence control output 1