An overview of the methods
An overview of the admin methods : Admin_xxx
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
11 An overview of the methods
11.1 An overview of the admin methods : Admin_xxx
Identifier/function Transfer value/data type Description
Admin_ModeCumulativeTime
Reads out the entire waiting time of the
given module.
Inputs
MM_Address
L_EATP_MM_Address
ID of the module the status of which
is to be requested. The value "0" and
L_EATP_CONST.OWNID address the
module's own ID.
eMode
L_EATP_Modes_PackML
Indicate the module the time
requirement of which is to be
displayed.
Return value/data type
Method
UDINT
Time in seconds
Admin_ModeCurrentTime
Reads out the waiting time since the
requested module has been in the current
mode.
Inputs
MM_Address
L_EATP_MM_Address
ID of the module the status of which
is to be requested. The value "0" and
L_EATP_CONST.OWNID address the
module's own ID.
Return value/data type
Method
UDINT
Time in seconds
Admin_ResetAllTimes
Reset of all times in all modes of the slave
module/own module to zero.
Inputs
MM_Address
L_EATP_MM_Address
ID of the module the status of which
is to be requested. The value "0" and
L_EATP_CONST.OWNID address the
module's own ID.
Admin_ResetCurrentModeTimes
Reset of all times in the current mode of the
slave module/own module to zero.
Inputs
MM_Address
L_EATP_MM_Address
ID of the module the status of which
is to be requested. The value "0" and
L_EATP_CONST.OWNID address the
module's own ID.
Admin_StateCumulativeTime
Reads out the entire waiting time of the slave
module/own module in the current mode/
state.
Inputs
MM_Address
L_EATP_MM_Address
ID of the module the status of which
is to be requested. The value "0" and
L_EATP_CONST.OWNID address the
module's own ID.
eMode
L_EATP_Modes_PackML
Mode, the time of which has to be
read out.
eState
L_EATP_States_PackML
Status, the time of which has to be
read out.
Return value/data type
Method
UDINT
Time in seconds