1 About this documentation
1.3 Terminology used
10
Lenze · 8400 BaseLine C · Reference manual · DMS 1.6 EN · 01/2014 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
1.3 Terminology used
Term Meaning
»Engineer« Lenze PC software which supports you in "engineering" (parameterisation, diag-
nostics and configuration) throughout the whole life cycle, i.e. from planning to
maintenance of the commissioned machine.
Application A technology application is a drive solution equipped with Lenze's experience
and know-how in which function and system blocks interconnected to a signal
flow are the basis for implementing typical drive tasks.
ASM Asynchronous motor
CINH Abbreviation: Controller inhibit (pulse inhibit)
Code Parameter used for controller parameterisation or monitoring. The term is usu-
ally called "index".
DC-injection braking DC injection braking is to brake and/or hold the motor. For this purpose, the
8400 BaseLine C creates a quasi DC field at the stator of the asynchronous ma-
chine. The energy to be dissipated is converted into heat in the rotor.
DCTRL Abbreviation: Drive control (device control)
Display code Parameter that displays the current state or value of an input/output of a sys-
tem block.
EPM Memory module on which all parametes of the drive system are saved non-vola-
tilely. These include the parameters of the controller and communication-rele-
vant parameters for the communication unit used.
Function block A function block can be compared with an integrated circuit that contains a cer-
tain control logic and delivers one or several values when being executed.
• Each function block has a unique identifier, e.g. "L_MPot_1" (motor potentio-
meter function)
Holding brake The holding brake serves to hold the rotor by means of a mechanical unit.
LA Abbreviation: Lenze Application block
• Example: "LA_NCtrl" – block for the "actuating drive speed" application.
Lenze setting This setting is the default factory setting of the device.
LP Abbreviation: Lenze Port block
• Example: "LP_Network_In" – port block for fieldbus communication.
LS Abbreviation: Lenze System block
• Example: "LS_DigitalInput" – system block for digital input signals.
MCTRL Abbreviation: Motor control
Port block Block for implementing the process data transfer via a fieldbus
QSP Quick stop ("Quick stop):
The motor control is decoupled from the setpoint selection and within a parame-
terisable deceleration time, the motor is brought to a standstill (n
act
=0).
Service brake The service brake serves to shutdown rotary or translatory masses in motion in
a controlled manner. The energy to be dissipated in this process is converted into
heat in the form of friction energy. This process is a regular and recurring opera-
ting mode.
SLVC Motor control: Sensorless vector control ("SensorLess Vector Control")
SM Synchronous motor
Subcode If a code contains several parameters, the individual parameters are stored un-
der "subcodes".
This manual uses a slash "/" as a separator between code and subcode
(e.g. "C118/3").
The term is usually called "subindex".
System block In the application, system blocks provide interfaces to basic functions and to the
hardware of the controller (e.g. to the digital inputs).
Comentarios a estos manuales