7 Parameter reference
7.1 Parameter list | C15030
54
Lenze · 8400 protec · Drive-based safety · Software Manual · DMS 2.4 EN · 05/2013 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C15030
C15031
C15032
Parameter | Name:
C15030 | SD-In Sensor type
Data type: UNSIGNED_8
Index: 9545
d
= 2549
h
Configuration of sensor types which are connected to the safe inputs.
Selection list
0 Input is deactivated
1 Passive sensor
2 Active sensor
Subcodes Information
C15030/1 SD-In1 sensor type
C15030/2 SD-In2 sensor type
Read access Write access CINH PLC STOP No transfer Scaling factor: 1
Parameter | Name:
C15031 | SD-In Sensor function
Data type: UNSIGNED_8
Index: 9544
d
= 2548
h
Function configuration of the safe inputs.
Selection list Information
0 Free assignment Safety function set in C15032.
1 Emergency stop
2 Operation mode selector
3 Enable switch
Subcodes Information
C15031/1 SD-In1 sensor function
C15031/2 SD-In2 sensor function
Read access Write access CINH PLC STOP No transfer Scaling factor: 1
Parameter | Name:
C15032 | SD-In Free assignment
Data type: UNSIGNED_8
Index: 9543
d
= 2547
h
Assignment of a safety function to a safe input.
• Only possible if the sensor function "Free assignment" is set for the safe input in C15031.
Selection list Information
0 STO Safe torque off (STO)
1 SS1 Safe stop 1 (SS1)
9 No function
Subcodes Information
C15032/1 SD-In1 free assignment
C15032/2 SD-In2 free assignment
Read access Write access CINH PLC STOP No transfer Scaling factor: 1