Drive PLC Developer Studio
L
34 DDS DE/EN 2.1
Channel creation with default parameters:
• Select Communication parameter from the dialog box. Then click the entry
local h os t
➞
➞➞
➞Lenze standard and confirm the entry with OK.
Configuration “Lenze standard” (cannot be changed):
Settings: standard:
Communciation driver: CAN 8220 Lenze system bus dongle driver
Parameter: Possible settings
Parameter channel: 1, 2, configurator configurator
CAN bus node address: 1..63
CAN bus baud rate: 5, 10, 20, 50, 100, 125, 250, 500, 1000, configurator configurator
Configuration “Lenze OPC” (cannot be changed):
Settings: standard:
Communciation driver: System bus server driver
Parameter: Possible settings
CAN bus node address: 1..63
Channel creation with detected/desired parameters:
1. Click New, to open the dialog box Communication parameter: New channel and to configure a
new channel.
2. The input field Name already shows a name for the new channel. It is however possible to
change the name.
3. Select one entry e. g. CAN 8220.
4. Confirm t he selection with OK.
5. Select the new channel and enter the corresponding communication parameters by using the
arrow keys.
6. Accept the settings with OK.
Note!
If the establishment of a connection to a target system is faulty, please start the system bus
configuration tool.
Start
➞
➞➞
➞Program➞
➞➞
➞Lenze➞
➞➞
➞Communication➞
➞➞
➞Systembus configuration tool
Select an adapter (e.g. 2173) and click Dian ostics in t he register General.
Tip!
Confirm the function key <F1> in the dialog box Communication parameter, to call the online help and
further information on the setting of communication parameters.