Mounting ECSxA axis module
Control cable/system bus cable
EDKCSZS000 DE/EN/FR 4.1
15
H2_MotLtg_BremsLtg_EN-ECSCS000_ECSXA_Steuerrltg_Sysbusltg_BL_EN
Control cable/system bus cable
Mounting the wire clamps Connecting the shield
5
6
ecs081 ecs082
Screw the wire clamps for the shield
connections of the control cable and the
system bus cable tightly onto the axis
module using a 3 mm Allan key.
Press the wire clamps for the shield
connections of the control cable and the
system bus cable down using a screw driver
(3 mm blade).
Place the cables under the wire clamps.
Remove the screw driver