Lenze E84AYCPM Manual de usuario Pagina 30

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 115
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 29
Lenze · E84AYCPM communication module (PROFIBUS®) · Communication Manual · DMS 5.0 EN · 11/2012 · TD17 30
6 Commissioning
6.1 Before initial switch-on
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
6 Commissioning
During commissioning, plant-specific data such as motor parameters, operating parameters,
responses, and parameters for fieldbus communication are defined for the inverter. Lenze devices
use codes for this purpose.
The codes of the inverter and for communication are saved to the memory module in a non-volatile
data set.
In addition, there are codes for diagnosing and monitoring the stations.
Parameter reference
( 95)
6.1 Before initial switch-on
Stop!
Before switching on the inverter for the first time, check ...
the entire wiring for completeness, short circuit and earth fault.
whether the bus system is terminated by means of a bus terminating resistor at the
first and last physical bus station.
Activating the bus terminating resistor
( 27)
Vista de pagina 29
1 2 ... 25 26 27 28 29 30 31 32 33 34 35 ... 114 115

Comentarios a estos manuales

Sin comentarios