13
quick
stop,
see
chapter
8
output armature
current
signal
The
output terminal
~
supplies
a
signal
proportional
to
the
armature
current.
(U
31)
=
5V
corresponds
approxi—
mately
to
the
nominal
current
of
the
controller
and can
be used
for the
direot
current display
with
a
measuring
instrument.
The maximum
bad
of
terminal
~
is
bOmA.
3
GND
Speed
controller
input
Terminal ~
leads
to
the
summation
point
of
the
speed
controller
via
Ri
50
k[2.
The
permissible
input
voltage
range
is
between +10V and
-10V.
When switching
the
controller
inhibit
the
input
is
switched
to
zero.
In
this oase
Ri
~
25
k[2.
For positive
set
value
or
positive
master
voltage
and negative
actual
value
a
positive
armature
voltage
is
applied
at
terminal
A.
GND,
controller
reference
point
input,
current
control,
Ri
~
10
kfi
output
speed controller,
Ri
~
200
fl.
The terminals ~
and
are
connected
internally
via
the
resistor R
705
on
soldering
posts.
For
current
ratio
control
or
connection
of an
external
current potentiometer
this
resistor must be
removed. The
desired maximum
armature
current
is
set
using
the
internal
trimmer
1
with
fully
open
external
current
potentiometer.
39
1.
durrerit
set
value
10
k/1
W
Im
Remove
R705
5]
El
5]
5]
5]