Electrical installation
Terminal box
Feedback system
6
EN
32
Lenze ¯ BA 33.0006 ¯ 3.0
6.4 Terminal box
Terminal box with knock out Terminal box with screwed connections
MT−terminal box−001.iso MT−terminal−box−002.iso
The openings in the terminal box are cast closed
and can be opened by the customer as required.
Note!
Open the holes on the underside of the knock out terminal box when the
cover is closed.
Cable glands and terminal studs for the power terminal box
Motor type /
motor size
Power connection
Screwed connections Terminal Terminal board
Cable
cross−section
[mm
2
]
Stripping length
[mm]
Tightening
torque [Nm]
Threaded
bolt
Tightening
torque [Nm]
MCA 10, 13,
14, 17
1 x M20 x 1.5 + 1 x M16 x 1.5 0.08 ... 2.5 10 ... 11
2)
−−−−− −−−−−
19, 21 1 x M32 x 1.5 + 1 x M25 x 1.5 0.2 ... 10 10 ... 11
2)
−−−−− −−−−−
20 2 x M20 + 2 x M 25 + 2 x M32 2.5 ... 16 18 ... 20
2)
−−−−− −−−−−
22
1 x M40x1.5 + 1 x M50x1.5 +
1 x M20x1.5 + 1 x M16x1.5
10 ... 35 18 3,2 −−−−− −−−−−
26
1 x M50 x 1.5 + 1 x M63 x 1.5 +
1 x M20 x 1.5 + 1 x M16 x 1.5
−−−−− M12 15.5
MQA 20 2 x M20 + 2 x M 25 + 2 x M32 2.5 ... 16 18 ... 20
2)
−−−−− −−−−−
22
1 x M40x1.5 + 1 x M50x1.5 +
1 x M20x1.5 + 1 x M16x1.5
10 ... 35 18 3.2 −−−−− −−−−−
26
1 x M50 x 1.5 + 1 x M63 x 1.5 +
1 x M20 x 1.5 + 1 x M16 x 1.5
−−−−− M12 15.5
MCS 09, 12,
14D,
14H,
14L15,
14P14,
19F15,
19J15
2 x M20 + 2 x M25 + 2 x M32
0.08 ... 2.5
1)
10 ... 11
2)
−−−−− −−−−−
14L32,
14P32,
19F13,
19J30,
19P
0.2 ... 10 10 ... 11
2)
−−−−− −−−−−
MDFQA 160 2 x M63 x 1.5 + 1 x M16 x 1.5 M12 15.5
MDKS 056,
071
1 x M20 x 1.5 + 1 x M16 x 1.5 0.08 ... 2.5 10 ... 11
2)
−−−−− −−−−−
Tab. 1 Cable glands and connecting terminals
1) 4 mm
2
without wire end ferrule
2) Spring terminal
Comentarios a estos manuales