Product description
Identification
Product key
3
EN
16
Lenze ¯ BA 33.0006 ¯ 3.0
5 Design, shaft, concentricity/vibrational severity/direct gearbox attachment
Design
A Standard flange form A/FF with through hole, cyl. shaft without keyway
B Standard flange form A/FF with through hole, cyl. shaft with keyway
C Standard flange form C/FT with threaded holes, cyl. shaft without keyway
N Standard flange form C/FT with threaded holes, cyl. shaft with keyway (standard attachment)
F Same as version A except that flange is large V Same as version N except that flange is large
G Same as version B except that flange is large O Without flange and without keyway
U Same as version C except that flange is large P Without flange and with keyway
Shaft
11 Shaft 11x23 (MCS06) 24 Shaft 24x50 (MCS14; MCA14, 17)
14 Shaft 14x30 (MCS09; MCA 10) 28 Shaft 28x60 (MCS19; MCA19)
19 Shaft 19x40 (MCS12; MCA13) 38 Shaft 38x80 (MCA21)
Concentricity/vibrational severity/direct gearbox attachment
N or R Concentricity/vibrational severity
Z0X Direct gearbox attachment: Motor without pinion for mounting on open gearbox with pinion; flange for direct gearbox attachment without intermediate cover, with
tapered hollow shaft
Y0X Direct gearbox attachment: Motor without pinion for mounting on open gearbox with pinion; flange for direct gearbox attachment with intermediate cover, with
tapered hollow shaft
6 Electrical connection, enclosure, cooling, load flywheel
Electrical connection
ST Separate circular connectors for power/brake, encoder/thermal detector, fan
SQ Shared rectangular connector for power, encoder...
KK Separate terminal boxes for power/brake, encoder/thermal detector/fan
KG Separate terminal boxes for power/brake, blower circular connectors for encoder, thermal detector
KS Terminal box for power+brake; circular connector for encoder and thermal detector; circular connector for blower
SK Circular connector for power+brake; circular connector for encoder+thermal detector; terminal box for fan
Enclosure
2 IP23 6 IP65 with shaft sealing ring
5 IP54 without shaft sealing ring (except for direct mounting on gearbox)
A IP64 (A−flange, without shaft sealing ring) / IP65
B IP54 with shaft sealing ring (A−bearing, oil−tight)
C IP54 with shaft sealing ring, double lip (A bearing dust−tight)
D IP65 with double−lip shaft sealing ring
Cooling
S00 Self cooling/without fan F10 Blower 230V; AC; 1N
F1F Blower 230V; AC; 1N; filter F30 Blower 400V; AC; 3N
F3F Blower 400V; AC; 3N; filter F50 Blower 115V; AC; 1N
FWO Blower 480V; AC; 3N FWF Blower 480V; AC; 3N; filter
Load flywheel
N Without additional load flywheel J With additional mass inertia
7 Motor protection, electron. nameplate, color/specification, approval
Temperature protection
B NC thermal contact R KTY sensor
E KTY sensor; electronic nameplate
Electronic nameplate
0 Standard nameplate 2 Second nameplate supplied loose
1 Standard nameplate + electronic nameplate 3 Second nameplate supplied loose + electronic nameplate
Colour/specification
S Colour: black
U
Specification − UL design and CSA design, approval
R
Specification − UL design, approval
8 Miscellaneous