L 2.1 EN - 09/2005 49
Cam Designer Basic
Functions
Cam Designer Basic Online Download
Repeat the above-described steps to create all cams required by means of the »Cam De-
signer Basic«.
After creating all profiles required by means of »Cam Designer Basic«, you can exit the
»Cam Designer Basic« with FileExit.
7.11 Cam Designer Basic Online Download
How to make an Online Download:
1. Switch the »Cam Designer Basic« online by clicking FileConnection to OPC server
or .
The button online/offline is only active if the LDS-DriveServer has been started.
The icon for the LDS-DriveServer is situated in the status bar.
If the red point in the icon becomes green, the system is online.
2. Select EditProject settings to open the Settings dialog box.
3. Select in Controller data the drive to which the data is to be downloaded.
4. Select FileCreate and download LCx-file or to activate the profile or cam
download.
The data for the current slave axis are written into the *.lcx-file.
After the download has been started with the button, a progress dialog appears.
Tip!
For the commissioning of production machines, the *.lc9-file can be attached to the
PLC program.
Note!
The download time increases if
a high bus load (cross communication) exists.
many data was changed.