Technical data
Electrical data
4
24
BA_CPCx8xx EN 3.0
Permissible ambient temperatures for systems with "Smart Cool" cooling
Standard device l With standard
hard disk
l With hard disk for
continuous
operation (24/7)
1)
l With hard disk for
extended
temperature
range
l Up to 1 GB RAM
l With CF card
l With DVD writer
drive
Processor [°C]
Intelâ Coreä Duo
1.66 GHz at max.
50 % CPU utilisation
2)
5 ... 45 5 ... 45 0 ... 45 5 ... 40
Intelâ Coreä Duo
1.66 GHz at max.
100 % CPU
utilisation
2)
5 ... 40 5 ... 40 0 ... 40 5 ... 40
1) We recommend replacing the hard disk after 30,000 operating hours or after 5 years.
2) The CPU utilisation can be determined via the Windows task manager (register "System performance")
4.2 Electrical data
Standard device
Supply
Voltage Current at 24 V
1)
Fuse Buffer battery
Intel
â
Core
Duoä
Intel
â
Atomä Type Type Service life
[V DC] [A] [A] [years]
CPC 2800 24 (+18 ... 30)
2)
1.4 0.8 35 34 > 6 (25 °C)
1) Without
ACU
UPS
control
unit,
DVD−Drive,
MC
card,
and
USB
consumer
2) With
ACU
UPS
Control
Unit
DC
+20
...
30 V
ACU UPS control unit (option)
Type
Operating voltage Max. current Charging current in operating
range
[V DC] [mA] [mA]
At 5 V At 12 V
ACU UPS 12 / 5 10 10 ... 600
1)
Approx. 250
1)
Subject to charging